Skip to content

Read QC — Sequencing and Alignment Metrics

In the app: QC & samples › Read QC

Available when the pipeline delivered its MultiQC general statistics (multiqc_general_stats.txt). Shown for every project kind, including variant projects.

Read QC answers the first question about any sequencing run: did every sample's reads come out of sequencing and alignment in reasonable shape? It shows the numbers the pipeline itself measured on the reads — read counts, mapping rates, duplication, GC, base quality, rRNA — side by side for every sample. Insights does not recompute any of them; it only compares each sample with the others, with the project's recorded settings and with the pipeline's run manifest.

Read QC — example output

Example output from a demonstration project with synthetic data.

Under the title, Inputs: names the files the report read (multiqc_general_stats.txt, and run_manifest.json when present).

Findings

The Findings box always opens with the same caution: "From the pipeline's MultiQC general statistics: the numbers the pipeline measured on the reads. Metrics it did not report are left out. Judge samples against their replicates."

Below it come warnings, only when something needs a look. They are worded as "check", not "fail", because what is normal depends on tissue, organism and library prep:

  • Input integrity — MD5 checksum, FASTQ validation or read-pair sync failed for some samples, or the pipeline recorded an error message for a sample.
  • Strandedness — samples disagree on the inferred strandedness; the project records one strandedness but samples are inferred otherwise; the pipeline flagged a declared-vs-inferred mismatch; or a sample was called stranded with under 80% of reads supporting the call.
  • Thresholds — rRNA above 10%, more than 5% of reads hitting a contaminant genome, under 60% uniquely mapped, or under 40% of reads assigned to genes. Each names the samples.
  • How the file was read — for example, an older QC file whose counts were delivered in millions and are shown as raw counts; count columns on different scales; reads mapped larger than total reads; rows for the same sample combined; samples that are not in the run's samplesheet; untrimmed runs.
  • Exclusions — samples the pipeline recorded as excluded from differential expression, with the recorded reason.

Charts

One bar chart per group of metrics, two per row, one bar per sample. A chart appears only when the pipeline reported at least one of its metrics, so a project shows a subset of these:

Chart Metrics
Read funnel Reads, Reads after trim, Reads mapped, Reads assigned
Trimming % Reads retained, % Pairs retained, % Adapter
Alignment % Mapped, % Uniquely mapped, % Multi-mapped, % Unmapped: too short, % Unmapped: mismatches, % Assigned
Insert size Median insert size (bp)
Composition % rRNA, % Mitochondrial, % Chloroplast, % Contaminant
Read quality % Duplication, % GC, % ≥ Q30
RNA QC: read distribution % Exonic, % Intronic, % Intergenic (stacked)
RNA QC: gene-body coverage Gene-body 3′ bias
Strandedness Strand fraction

On a typical RNA project you will see Read funnel, Alignment, Composition and Read quality; on a DNA project whose MultiQC table has fewer columns, perhaps only Read funnel and Read quality.

Raw data

Raw data — Per-sample metrics

One row per sample, one column per metric the pipeline reported, with Download CSV. The column names are those in the chart table above, plus:

Column Meaning
Sample Sample name
Reads Total reads. The label carries the unit — pairs or reads — and says legacy when an older file did not record it
Inferred strandedness The pipeline's strandedness call for the sample
Top contaminant The contaminant genome with most hits, when screened
Included in DE Whether the pipeline used the sample in differential expression (Included on variant projects), when the run manifest records it
Count unit, Subject (DE sample) Shown when the pipeline recorded them

Input integrity

When the pipeline reported integrity checks, a second table shows MD5 OK, FASTQ valid, Pairs in sync (✅ / ❌) and Integrity error for each sample.

Interactive / All options

Interactive (the default) is the view described above. All options shows the same report as the app's full report page, where the charts follow the Appearance settings in the Report settings panel (see Report Settings). The filter settings (p-value, fold change, genes) do not change this report.

Reading it

  • Compare a sample with its own replicates, not with an absolute number. A sample that stands apart from its group on several charts at once is the one to check.
  • Low % Uniquely mapped across every sample usually points to the reference (wrong organism or build); low % Assigned with good mapping points to the annotation or the strand setting.
  • High % Duplication is normal for some library types and very deep runs; it matters when one sample differs from its replicates.
  • Problems found here carry into every later report. To decide whether a sample stays in the analysis, use Sample QC.